<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.7//EN" "https://dtd.nlm.nih.gov/ncbi/pubmed/in/PubMed.dtd">
<ArticleSet>
<Article>
<Journal>
				<PublisherName>Shahrekord University</PublisherName>
				<JournalTitle>Journal of Microfluidic and Nanofluidic Research</JournalTitle>
				<Issn></Issn>
				<Volume>2</Volume>
				<Issue>1</Issue>
				<PubDate PubStatus="epublish">
					<Year>2025</Year>
					<Month>03</Month>
					<Day>01</Day>
				</PubDate>
			</Journal>
<ArticleTitle>Effect of Inlet Velocity and Voltage on the Mixing Performance of an Electroosmotic Device</ArticleTitle>
<VernacularTitle></VernacularTitle>
			<FirstPage>60</FirstPage>
			<LastPage>64</LastPage>
			<ELocationID EIdType="pii">11807</ELocationID>
			
<ELocationID EIdType="doi">10.22034/jmnr.2025.15166.1008</ELocationID>
			
			<Language>EN</Language>
<AuthorList>
<Author>
					<FirstName>Narges</FirstName>
					<LastName>Jafari Ghahfarokhi</LastName>
<Affiliation>Department of Mechanical Engineering, University of Isfahan, Isfahan, Iran</Affiliation>

</Author>
<Author>
					<FirstName>Ahmad</FirstName>
					<LastName>Najafpour</LastName>
<Affiliation>Department of Mechanical Engineering, Babol Noshirvani University of Technology, Babol, Iran</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
		<Abstract>Electroosmotic micromixers are utilized in microfluidic systems, especially in biochemical studies. This article examines an asymmetric electroosmotic micromixer to ascertain the effects of applied voltage and inlet velocity (Uin) on mixing index (MI) and pressure drop (Δp). It is shown that without altering Δp, the applied voltage greatly increases MI. For instance, when Uin= 0.2 mm/s, increasing the applied voltage from 0 to 1, 3, and 6 V improves MI by 2.31%, 2.53%, and 5.47%, respectively. MI is improved by 2.76%, 3.66%, and 8.38%, respectively, when the applied voltage is increased from 0 to 1, 3, and 6 V with Uin= 0.4 mm/s. MI is improved by 2.86%, 5.08%, and 11.81%, respectively, when the applied voltage is increased from 0 to 1, 3, and 6 V when Uin= 0.6 mm/s. MI is improved by 3.97%, 6%, and 13.22%, respectively, when the applied voltage is increased from 0 to 1, 3, and 6 V with Uin= 0.8 mm/s. For a given applied voltage, it is seen that Δp increases slightly when the inlet velocity is raised; also, Δp is an increasing function of the applied voltage for a given inlet velocity, despite the little increase.</Abstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">Microfluidic device</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Electroosmotic micromixer</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Pressure drop</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">Mixing index</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://jmnr.sku.ac.ir/article_11807_13c86fac19a52dbc843105b709dc71fc.pdf</ArchiveCopySource>
</Article>
</ArticleSet>